1. Purpose
    To evaluate posterior capsule opacification (PCO) and the impact of different intraocular lens (IOL) models on PCO characteristics using optical coherence tomography (OCT).

    Methods
    Eighty-three eyes with PCO (fibrosis or pearl type) and 32 pseudophakic eyes without PCO were included. Horizontal 3.0 mm long OCT scans of the posterior capsule were obtained. Measurements and means of the peak posterior capsule intensity (PCI) and posterior capsule thickness (PCT) (distance between 2 spikes at posterior capsule) at 3 scan points were recorded. The PCI and PCT were compared with best corrected visual acuity (BCVA) and IOL ... (Read Full Article)