-
Popular Articles
Quasi-simultaneous optical coherence tomography and confocal imaging
Fibres reinforced dentures investigated with en-face optical coherence tomography
Root canal filling evaluation using optical coherence tomography
Transmissive scanning delay line for optical coherence tomography
Compact high resolution imaging apparatus
Quality assessment of dental treatments using en-face optical coherence tomography
Optical mapping apparatus with adjustable depth resolution and multiple functionality
-
Quality assessment of dental treatments using en-face optical coherence tomography
Explore Article SPIE Digital Library (Oct 6 2008) Dentistry
Cosmin Sinescu, Meda Lavinia Negrutiu, Carmen Todea et al. The present study evaluates the potential of en-face optical coherence tomography (OCT) as a possible noninvasive high resolution method for supplying necessary information on the material defects of dental prostheses and microleakage at prosthetic interfaces. Teeth are also imaged after several tre ... [J. Biomed. Opt. 13, 054065 (2008)] published Mon Oct 6, 2008. (Read Full Article)
Comment on Article Mentions: Adrian G. Podoleanu University of Kent Adrian Bradu
-
Transmissive scanning delay line for optical coherence tomography
Explore Article PatFT » Page 1 of 1 (Aug 26 2008) Patents
FIELD OF THE INVENTION The invention refers to the field of path scanning, optical measurements, and more specifically to the field of high resolution optical imaging by means of optical coherence tomography. BACKGROUND OF THE INVENTIONOptical coherence tomography (OCT) is an interferometric imaging technique described, for example, in U.S. Pat. No. 5,975,697. In order to produce OCT scans in the depth direction, the optical path length between a reference beam ... (Read Full Article)
Comment on Article Mentions: Adrian G. Podoleanu OTI Ophthalmic Technologies Inc. John A. Rogers
-
Quasi-simultaneous optical coherence tomography and confocal imaging
Explore Article SPIE Digital Library (Jul 18 2008) Microscopy , Ophthalmology
Irina Trifanov, Michael Hughes, Adrian Gh. Podoleanu et al. A new approach of acquiring quasi-simultaneous optical coherence tomography (OCT) and confocal images is presented. The two images are generated using different principles, OCT and confocal microscopy. When the system is used to image the retina, the two images have depth resolutions, at present, of ... [J. Biomed. Opt. 13, 044015 (2008)] published Fri Jul 18, 2008. (Read Full Article)
Comment on Article Mentions: Adrian G. Podoleanu University of Kent New York Eye and Ear Infirmary
-
Fibres reinforced dentures investigated with en-face optical coherence tomography
Explore Article SPIE Digital Library (May 2 2008) Dentistry
Meda L. Negrutiu, Cosmin Sinescu, Michael Hughes et al. The complete dentures are currently made using different technologies. In order to avoid deficiencies of the prostheses made using the classical technique, several alternative procedures have been devised. In order to enhance the mechanical strength, complete denture bases are reinforced with fibres ... [Proc. SPIE Int. Soc. Opt. Eng. 6991, 69911U (2008)] published Fri May 2, 2008. (Read Full Article)
Comment on Article Mentions: Cosmin Sinescu Adrian G. Podoleanu University of Kent
-
Root canal filling evaluation using optical coherence tomography
Explore Article SPIE Digital Library (May 2 2008) Dentistry
Meda L. Negrutiu, Cosmin Sinescu, Michael Hughes et al. The root canal fillings are destined to seal the root canal especially in the apical areea. Invasive techniques are known which are used to assess the quality of the seal. These lead to the destruction of the probes and often no conclusion could be drawn in respect to the existence of any microleaka ... [Proc. SPIE Int. Soc. Opt. Eng. 6991, ... (Read Full Article)
Comment on Article Mentions: Cosmin Sinescu Adrian G. Podoleanu University of Kent
-
An optical coherence tomography investigation of materials defects in ceramic fixed partial dental prostheses
Explore Article SPIE Digital Library (May 2 2008) Dentistry
Cosmin Sinescu, Meda Negrutiu, Michael Hughes et al. Metal ceramic and integral ceramic fixed partial prostheses are mainly used in the frontal part of the dental arch because for esthetics reasons. The masticatory stress may induce fractures of the bridges. There are several factors that are associated with the stress state created in ceramic restora ... [Proc. SPIE Int. Soc. Opt. Eng. 6991, 69910O (2008)] published Fri May 2, 2008. (Read Full Article)
Comment on Article Mentions: Cosmin Sinescu Adrian G. Podoleanu University of Kent
-
Compact high resolution imaging apparatus
Explore Article PatFT » Page 1 of 1 (Feb 12 2008) Patents
An optical coherence tomography (OCT) apparatus includes an optical source, an interferometer generating an object beam and a reference beam, a transverse scanner for scanning an object with said object beam, and a processor for generating an OCT image from an OCT signal returned by said interferometer. At least the optical source, the interferometer, and the scanner are mounted on a common translation stage displaceable towards and away from said ... (Read Full Article)
Comment on Article Mentions: John A. Rogers Adrian G. Podoleanu University of Kent
-
Optical mapping apparatus with adjustable depth resolution and multiple functionality
Explore Article PatFT » Page 1 of 1 (Aug 3 2004) Microscopy , Ophthalmology , Patents
The present invention relates to a multiple channel optical mapping apparatus which can deliver one or simultaneously at least two images of different depth resolutions or sequentially, images with different depth resolutions, or a combination of these images, or a single image with adjustable depth resolution. The multiple channels could be either multiple confocal channel and one or two optical coherence tomography channel, or two optical coherence tomography channels, or ... (Read Full Article)
Comment on Article Mentions: George M. Dobre Adrian G. Podoleanu John A. Rogers
-
Optical mapping apparatus with adjustable depth resolution
Explore Article PatFT » Page 1 of 1 (Nov 2 1999) Ophthalmology , Patents
Optical mapping apparatus with adjustable depth resolution is provided. The optical mapping apparatus can display transversal images in an object, particularly the eye. The apparatus can deliver two or more images with different depth resolutions, or a combination of these images, or only one image with adjustable depth resolution. There is also provided optical mapping apparatus with adjustable depth resolution, where OCT images are corrected for the curvature at the ... (Read Full Article)
Comment on Article Mentions: Adrian G. Podoleanu OTI Ophthalmic Technologies Inc.






Recent Comments
Eric Swanson » The Evolution of Spectral Domain OCT
For more information see http://octnews.hivefire.com/entity/profile/oct-information-on-ophthalmology-website/
bernie » Morphology and Epidermal Thickness of Normal Skin Imaged by Optical Coherence Tomography.
Interesting
See all recent comments