Polarization effect on the depth resolution of optical coherence tomography
Explore Article SPIE Digital Library (Dec 11 2008)
Shuliang Jiao and Marco Ruggeri We find for the first time that polarization mismatch of the sample and reference arms in optical-fiber-based optical coherence tomography (OCT) has critical effect on its depth resolution when the light source is partially polarized. When the polarization states of the two arms are matched, the mea ... [J. Biomed. Opt. 13, 060503 (2008)] published Thu Dec 11, 2008. (Read Full Article)
Comment on Article Mentions: Shuliang Jiao Marco Ruggeri University of Miami
-
Direct visualization of tear film on soft contact lens using ultra-high resolution spectral domain optical coherence tomography
Explore Article SPIE Digital Library (Feb 11 2008) Ophthalmology
Jianhua Wang, Shuliang Jiao, Marco Ruggeri et al. The integrity of the tear film on the surface of contact lenses is essential to maintaining visual clarity and the overall health of the superficial structures of the eye (cornea and conjunctiva) for contact lens wearers. It is very critical to evaluate pre- and post-lens tear films in contact lens ... [Proc. SPIE Int. Soc. Opt. Eng. 6844, 68441E (2008)] published Mon ... (Read Full Article)
Comment on Article Mentions: Shuliang Jiao Jianhua Wang Marco Ruggeri
-
In vivo imaging of raptor retina with ultra high resolution spectral domain optical coherence tomography
Explore Article SPIE Digital Library (Feb 11 2008) Ophthalmology
Marco Ruggeri, James C. Major, Jr., Craig McKeown et al. Among birds, raptors are well known for their exceptional eyesight, which is partly due to the unique structure of their retina. Because the raptor retina is the most advanced of any animal species, in vivo examination of its structure would be remarkable. Furthermore, a noticeable percentage of tra ... [Proc. SPIE Int. Soc. Opt. Eng. 6844, 684402 (2008)] published Mon ... (Read Full Article)
Comment on Article Mentions: Marco Ruggeri
-
Automatic retinal blood flow calculation using spectral domain optical coherence tomography
Explore Article opticsinfobase.org (Nov 7 2007) Ophthalmology
Keywords (OCIS): (110.4500) Imaging systems : Optical coherence tomography (120.3890) Instrumentation, measurement, and metrology : Medical optics instrumentation (170.4580) Medical optics and biotechnology : Optical diagnostics for medicine Abstract Optical Doppler tomography (ODT) is a branch of optical coherence tomography (OCT) that can measure the speed of a blood flow by measuring the Doppler shift impinged on the probing sample light by the moving blood cells. However, the measured speed (Read Full Article)
Comment on Article Mentions: Marco Ruggeri Shuliang Jiao Carmen A. Puliafito






Recent Comments
Eric Swanson » The Evolution of Spectral Domain OCT
For more information see http://octnews.hivefire.com/entity/profile/oct-information-on-ophthalmology-website/
bernie » Morphology and Epidermal Thickness of Normal Skin Imaged by Optical Coherence Tomography.
Interesting