Fuchs’ Endothelial Dystrophy in 830-nm Spectral Domain Optical Coherence Tomography
Explore Article Ophthalmic Surgery, Lasers and Imaging (Sep 10 2008) Ophthalmology
This article presents for the first time the potential of 830-nm spectral domain optical coherence tomography (SD-OCT) in the evaluation of Fuchs’ endothelial dystrophy. SD-OCT is an imaging technique that can be used for in vivo cross-sectional corneal visualization. The important features of SD-OCT instruments include improved sensitivity and short acquisition time, which improves the quality of the tomograms compared with conventional time domain OCT. Tomograms of the corneas of ... (Read Full Article)
Comment on Article Mentions: Maciej Wojtkowski Nicolaus Copernicus University Andrzej A. Kowalczyk
-
Granular Corneal Dystrophy in 830-nm Spectral Optical Coherence Tomography.
Explore Article Cornea (Jul 23 2008) Ophthalmology
Page: 830DOI: 10.1097/ICO.0b013e31816be90fAuthors: Kaluzny, Bartlomiej J PhD; Szkulmowska, Anna MSc; Szkulmowski, Maciej MSc; Bajraszewski, Tomasz MSc; Wawrocka, Anna MSc; Krawczynski, Maciej R PhD; Kowalczyk, Andrzej PhD; Wojtkowski, Maciej PhD (Read Full Article)
Comment on Article Mentions: Nicolaus Copernicus University Maciej Wojtkowski Andrzej A. Kowalczyk
-
Spectral Optical Coherence Tomography in Video-Rate and 3D Imaging of Contact Lens Wear
Explore Article Optometry and Vision Science (Feb 15 2008) Ophthalmology
Optometry & Vision Science. 84(12):E1104-E1109, December 2007. KALUZNY, BARTLOMIEJ J. MD, PhD; FOJT, WOJCIECH Dipl Ing; SZKULMOWSKA, ANNA MSc; BAJRASZEWSKI, TOMASZ MSc; WOJTKOWSKI, MACIEJ PhD; KOWALCZYK, ANDRZEJ PhD Abstract: Purpose. To present the applicability of spectral optical coherence tomography (SOCT) for video-rate and three-dimensional imaging of a contact lens on the eye surface. Methods. The SOCT prototype instrument constructed at Nicolaus Copernicus University (Torun, Poland) is b (Read Full Article)
Comment on Article Mentions: Nicolaus Copernicus University Andrzej A. Kowalczyk Tomasz Bajraszewski
-
Mapping of photoreceptor dysfunction using high resolution three-dimensional spectral optical coherence tomography
Explore Article SPIE Digital Library (Feb 11 2008) Ophthalmology
B. L. Sikorski, M. Szkulmowski, J. J. Kaluzny et al. The ability to obtain reliable information on functional status of photoreceptor layer is essential for assessing vision impairment in patients with macular diseases. The reconstruction of three-dimensional retinal structure in vivo using Spectral Optical Coherence Tomography (Spectral OCT) became p ... [Proc. SPIE Int. Soc. Opt. Eng. 6844, 68440J (2008)] published Mon Feb 11, 2008. (Read Full Article)
Comment on Article Mentions: Bartlomiej J. Kaluzny Maciej Wojtkowski Andrzej A. Kowalczyk






Recent Comments
Eric Swanson » The Evolution of Spectral Domain OCT
For more information see http://octnews.hivefire.com/entity/profile/oct-information-on-ophthalmology-website/
bernie » Morphology and Epidermal Thickness of Normal Skin Imaged by Optical Coherence Tomography.
Interesting
See all recent comments