Search the article archives
 
Total: 2,095 articles

Powered by HiveFire
Optical Coherence Tomography News

Home | All Articles | Entities | Email Newsletter | Comments | Login | Register

Categories: Bronchoscopy, Cardiology, Dentistry, Dermatology, Endoscopy, Glucose, Microscopy, Non-Medical, Ophthalmology, Acquisition, Funding, Jobs & Studentships, Partnership, Patents

Articles for category "Dentistry"
Dr. Craig Gimbel, Executive Vice President of Clinical Affairs for Lantis Laser [video]
TV.WallSt.net (Jul 1 2008) Dentistry
Lantis was formed to commercialize the application of novel technologies in the dental industry. The criteria for selected products include competitive edge, exclusivity and large market potential. Lantis is currently in Phase 2 and Phase 3 development, moving through beta systems, product development and application for FDA clearance and plans to launch the OCT Dental Imaging System(tm) in the first quarter of 2009. Lantis has exclusive rights to the application ...
Lantis Laser's Dental Diagnostic Imaging System Can Address Ada's ...
PrimeNewswire, Inc. (Jun 26 2008) Dentistry
Lantis' OCT (Optical Coherence Tomography) Diagnostic Imaging System(tm) will assist the clinician in making an evidence-based decision to place the sealant ...
Non-destructive assessment of inhibition of demineralization in dental enamel irradiated by a = 9.3-µm CO2 laser at ablative irradiation intensities with PS-OCT
www3.interscience.wiley.com (Jun 21 2008) Dentistry
Background and Objective Polarization sensitive optical coherence tomography (PS-OCT) has great promise for the non-destructive assessment of the efficacy of anti-caries agents such as fluoride and thermal laser treatments on enamel surfaces. The purpose of this study was to demonstrate that PS-OCT can be used to measure demineralization in craters/incisions prepared in enamel by a CO2 laser operating at the high irradiation intensities required for cavity preparations. Materials and Methods ...
Non-destructive assessment of inhibition of demineralization in dental enamel irradiated by a lambda = 9.3-microm CO(2) laser at ablative irradiation intensities with Ps-oct.
NCBI HomePage (Jun 20 2008) Dentistry
Non-destructive assessment of inhibition of demineralization in dental enamel irradiated by a lambda = 9.3-microm CO(2) laser at ablative irradiation intensities with PS-OCT. Lasers Surg Med. 2008 Jun 18;40(5):342-349 Authors: Can AM, Darling CL, Ho C, Fried D BACKGROUND AND OBJECTIVE: Polarization sensitive optical coherence tomography (PS-OCT) has great promise for the non-destructive assessment of the efficacy of anti-caries agents such as fluoride and thermal laser treatments on enamel surfaces. ...
Lantis Laser Commences Phase 3 Development of Its OCT Light-Based Dental Imaging System
PrimeNewswire, Inc. (Jun 11 2008) Dentistry, Acquisition
DENVILLE, N.J., June 10, 2008 (PRIME NEWSWIRE) -- Lantis Laser Inc. (Pink Sheets:LLSR) (http://www.lantislaser.com), announced today that it has commenced Phase 3 of the development cycle of its proprietary, highly advanced Optical Coherence Tomography (OCT) Dental Imaging System(tm). The OCT System is a diagnostic light-based, chairside, system that images in real-time at a resolution of up to 10 times x-ray and without any harmful radiation. It is expected to have ...
Lantis Develops Light-Based Dental Imaging System
FDA News (Jun 10 2008) Dentistry
Lantis Laser has begun Phase III in the development of its optical dental imaging system.
Axsun Technologies Announces Strategic Supply Agreement for ...
newsblaze.com (Jun 3 2008) Dentistry, Partnership
Under this multi-year exclusive agreement for Optical Coherence Tomography (OCT) dental imaging, Axsun will supply the Integrated Optical Coherence ...
Lantis Laser Secures Exclusive Worldwide Rights to Axsun's ...
PrimeNewswire, Inc. (Jun 3 2008) Dentistry, Partnership
... MA, whereby AXSUN will manufacture and supply the Integrated Optical Coherence Tomography (OCT) Engine for Lantis' OCT Dental Imaging System(tm), ...
Lantis Laser Secures Exclusive Worldwide Rights to Axsun's Advanced Tunable Laser Engine for its OCT Dental Imaging ...
Top News Archive (Jun 3 2008) Dentistry, Partnership
DENVILLE, N.J., June 3, 2008 -- Lantis Laser Inc. announced today it has signed a Strategic Agreement with AXSUN Technologies, of Billerica, MA, whereby AXSUN will manufacture and supply the Integrated Optical Coherence Tomography Engine for Lantis' OCT Dental Imaging System, to be introduced to dentistry in the first quarter of 2009.
Apparatus For Dental Oct Imaging (Wo 2008/063605)
wipo.int (May 29 2008) Dentistry, Patents
An apparatus (10) for obtaining an image of a tooth (20) includes an image sensor and a white light source (12) providing broadband polychromatic light and an ultraviolet light source providing narrow-band light. A combiner (15) directs broadband polychromatic light and narrow band light along a common illumination path to illuminate the tooth. A polarization beamsplitter (18) directs polarized light from the illumination path along an optical axis (216). An ...
Diagnosis of Vertical Root Fractures with Optical Coherence Tomography
jendodon.com (May 24 2008) Dentistry
The purpose of this experiment was to evaluate the ability of optical coherence tomography (OCT) to image vertical root fractures (VRFs). Twenty-five mandibular premolars were prepared to size 50. Five teeth served as controls. Group 1 (n = 10) was treated with ethylenediaminetetraacetic acid and ultrasonic irrigation, whereas group 2 (n = 10) received no further treatments. Teeth from groups 1 and 2 were fractured, and the presence of a ...
Diagnosis of vertical root fractures with optical coherence tomography.
NCBI HomePage (May 24 2008) Dentistry
Related Articles Diagnosis of vertical root fractures with optical coherence tomography. J Endod. 2008 Jun;34(6):739-42 Authors: Shemesh H, van Soest G, Wu MK, Wesselink PR The purpose of this experiment was to evaluate the ability of optical coherence tomography (OCT) to image vertical root fractures (VRFs). Twenty-five mandibular premolars were prepared to size 50. Five teeth served as controls. Group 1 (n = 10) was treated with ethylenediaminetetraacetic acid and ...
Fibres reinforced dentures investigated with en-face optical coherence tomography
SPIE Digital Library (May 2 2008) Dentistry
Meda L. Negrutiu, Cosmin Sinescu, Michael Hughes et al. The complete dentures are currently made using different technologies. In order to avoid deficiencies of the prostheses made using the classical technique, several alternative procedures have been devised. In order to enhance the mechanical strength, complete denture bases are reinforced with fibres ... [Proc. SPIE Int. Soc. Opt. Eng. 6991, 69911U (2008)] published Fri May 2, 2008.
Root canal filling evaluation using optical coherence tomography
SPIE Digital Library (May 2 2008) Dentistry
Meda L. Negrutiu, Cosmin Sinescu, Michael Hughes et al. The root canal fillings are destined to seal the root canal especially in the apical areea. Invasive techniques are known which are used to assess the quality of the seal. These lead to the destruction of the probes and often no conclusion could be drawn in respect to the existence of any microleaka ... [Proc. SPIE Int. Soc. Opt. Eng. 6991, ...
Investigation of bracket bonding for orthodontic treatments using en-face optical coherence tomography
SPIE Digital Library (May 2 2008) Dentistry
Cosmin Sinescu, Meda L. Negrutiu, Michael Hughes et al. Despite good diagnosis and treatment planning, orthodontic treatment can fail if bonding fails. It is now common practice to address the aesthetic appearance of patients using aesthetic brackets instead of metal ones. Therefore, bonding aesthetic brackets has become an issue for orthodontists today. ... [Proc. SPIE Int. Soc. Opt. Eng. 6991, 69911M (2008)] published Fri May 2, 2008.
An optical coherence tomography investigation of materials defects in ceramic fixed partial dental prostheses
SPIE Digital Library (May 2 2008) Dentistry
Cosmin Sinescu, Meda Negrutiu, Michael Hughes et al. Metal ceramic and integral ceramic fixed partial prostheses are mainly used in the frontal part of the dental arch because for esthetics reasons. The masticatory stress may induce fractures of the bridges. There are several factors that are associated with the stress state created in ceramic restora ... [Proc. SPIE Int. Soc. Opt. Eng. 6991, 69910O (2008)] published Fri May 2, 2008.
Early dental caries detection using a fibre-optic coupled polarization-resolved Raman spectroscopic system
opticsinfobase.org (Apr 21 2008) Dentistry
Alex C. Ko, Mark Hewko, Michael G. Sowa, Cecilia C. Dong, Blaine Cleghorn, Lin-P'ing Choo-Smith A new fibre-optic coupled polarization-resolved Raman spectroscopic system was developed for simultaneous collection of orthogonally polarized Raman spectra in a single measurement. An application of detecting incipient dental caries based on changes observed in Raman polarization anisotropy was ... [Opt. Express 16, 6274-6284 (2008)]
Lantis Laser partners with Axsun to deploy frequency-domain OCT for Dentistry
BioOptics World (Apr 9 2008) Dentistry, Partnership
April 9, 2008, Denville, NJ--Lantis Laser has entered into a strategic relationship with Axsun Technologies to incorporate Axsun's patented swept-source optical coherence tomography (OCT) technology into Lantis' dental imaging systems.
Optical coherence tomography imaging
PatFT, AppFT (Apr 8 2008) Dentistry, Patents
A digitized image of an object may include representations of portions of the object that are obscured, occluded or otherwise unobservable. The image may be a multi-dimensional visual representation of dentition. Characteristics of the dentition and its surfaces, contours, and shape may be determined and/or analyzed. A light may be directed toward and reflected from the dentition. The reflected light may be combined with a reference to determine characteristics of ...
LOW COHERENCE DENTAL OCT IMAGING
wipo.int (Mar 20 2008) Dentistry, Patents
A method for obtaining an image of a tooth obtains an area image of the tooth (20) surface and identifies a region of interest from the area image by positioning a marker (146) on the area image. The marker (146) corresponds to at least a portion of the region of interest and identifies a scanning area. An optical coherence tomography (OCT) image is then obtained over the scanning area.
Strategic Agreement w/Axsun Technologies to Upgrade Technology
The NASDAQ Stock Market (Mar 17 2008) Dentistry, Partnership
Lantis Laser Inc. (LLSR) has entered into a strategic relationship with Axsun Technologies, a designer of high-performance Integrated MEMs OCT Engines.
Lantis Laser Enters Strategic Partnership Enabling Major Upgrade ...
PrimeNewswire, Inc. (Mar 17 2008) Dentistry, Partnership
Axsun's patented swept source technology enables the highest attainable performance for frequency domain optical coherence tomography, a novel and rapidly ...
Lantis Laser Enters Strategic Partnership Enabling Major Upgrade to Its Dental Imaging System
Top News Archive (Mar 17 2008) Dentistry, Partnership
DENVILLE, N.J., March 17, 2008 -- Lantis Laser Inc. , announced today that it has entered into a strategic relationship with Axsun Technologies, leaders in the design of high-performance Integrated MEMs OCT Engines.
Characterization of Dentin and Enamel by use of Optical Coherence Tomography.
NCBI HomePage (Mar 6 2008) Dentistry
Related Articles Characterization of Dentin and Enamel by use of Optical Coherence Tomography. Appl Opt. 1999 Apr 1;38(10):2092-6 Authors: Wang XJ, Milner TE, de Boer JF, Zhang Y, Pashley DH, Nelson JS Optical coherence tomographic images of human dentin and enamel are obtained by use of polarization-sensitive optical coherence tomography. A birefringence effect in enamel (lambda = 856 nm) and light propagation along dentinal tubules are observed. The group index ...