Related Entities
Carl Zeiss Meditec OCT News
31 articles also mentioned Carl Zeiss Meditec
Carl Zeiss Meditec OCT News
15 articles also mentioned Zeiss Stratus OCT
Carl Zeiss Meditec Delivers Key Technological Advances in Optical Coherence Tomography
5 articles also mentioned Jim Taylor
High-resolution optical coherence tomography to evaluate vitreomacular traction before and after membrane peeling.
3 articles also mentioned Medical University of Vienna
Carl Zeiss Meditec Delivers Key Technological Advances in Optical Coherence Tomography
3 articles also mentioned Peter K. Kaiser
Carl Zeiss Meditec Delivers Key Technological Advances in Optical Coherence Tomography
3 articles also mentioned Cleveland Clinic
Carl Zeiss Meditec: Largest base of optical coherence technology worldwide with more than 10.000 units installed
3 articles also mentioned Zeiss Visante OCT
-
Mentioned In 34 Articles
-
Quality of Threshold Algorithm in Age-related Macular Degeneration: Stratus versus Cirrus OCT
iovs.org (Nov 26 2008) Ophthalmology Explore Article
...e accuracy of threshold algorithm lines of Stratus optical coherence tomography (OCT) with those of Cirrus OCT. Methods: A consecutive series of patients aged at least 50 years with exudative age-related ma... (Read Full Article)
Comment on Article Mentions: Medical University of Vienna Carl Zeiss Meditec Zeiss Cirrus HD-OCT
-
The Evolution of Spectral Domain OCT
ophmanagement.com (Nov 10 2008) Ophthalmology Explore Article
Comment "For more information see http://octnews.hivefire.com/entity/profile/oct-information-on-ophthalmology-website/" - Eric Swanson
...ally sight-saving advance. Current Options In 2007, only four SDOCT devices were on the market: the Cirrus HD-OCT (Carl Zeiss Meditec), the Spectralis OCT and Spectralis HRA+OCT (Heidelberg) and the RTVue-100 (Opt...
(Read Full Article)
1 Comment Mentions: Optovue Heidelberg Engineering Topcon Medical Systems
-
Carl Zeiss Meditec Introduces New Suite of Ophthalmic Innovations
MarketWatch.com (Nov 8 2008) Ophthalmology Explore Article
... care," saidIke Ahmed, MD, Assistant Professor at the University of Toronto, Ontario. "As a user of Cirrus HD-OCT, IOLMaster, Atlas, Visante OCT and GDx,I find that the newest products have evolved to not only del... (Read Full Article)
Comment on Article Mentions: Zeiss Stratus OCT Zeiss Visante OCT Michael Kaschke
-
Three Dimensional Optical Coherence Tomography (3D-OCT) Image Enhancement with Segmentation Free Contour Modeling C-Mode
iovs.org (Oct 28 2008) Ophthalmology Explore Article
...ntation. Methods: Using two SD-OCT devices (an ultrahigh resolution prototype of our own design and Cirrus OCT (Carl Zeiss Meditec, Dublin, CA)), we obtained 3D SD-OCT data within 6x6x1.4 mm and 6x6x2 mm vo... (Read Full Article)
Comment on Article Mentions: University of Pittsburgh Massachusetts Institute of Technology James G. Fujimoto
-
Prospective Comparison of Cirrus and Stratus Optical Coherence Tomography for Quantifying Retinal Thickness
American Journal of Ophthalmology (Oct 16 2008) Ophthalmology Explore Article
Purpose: To compare Cirrus Fourier-domain optical coherence tomography (OCT) with Stratus time-domain OCT for imaging retinal ... (Read Full Article)
Comment on Article Mentions: Zeiss Stratus OCT Zeiss Cirrus HD-OCT Carl Zeiss Meditec
-
Modified OCT device provides higher-resolution images than current technology
Ophthalmology Times (Oct 5 2008) Ophthalmology Explore Article
...ified version of a commercially available high-definition (HD) optical coherence tomography device (Cirrus OCT, Carl Zeiss Meditec), adapted for imaging the anterior chamber angle, was able to provide highe... (Read Full Article)
Comment on Article Mentions: Carl Zeiss Meditec Zeiss Cirrus HD-OCT
-
Spectral-Domain Cirrus Optical Coherence Tomography of Choroidal Striations Seen in the Acute Stage of Vogt-Koyanagi-Harada Disease
American Journal of Ophthalmology (Oct 1 2008) Ophthalmology Explore Article
Purpose: To describe changes in the retinal pigment epithelium (RPE) corresponding to the choroidal striations in acute-stage Vogt-Koyanagi-Harada (VKH) disease.Design: Prospective, consecutive case series.Methods: Four patients (eight eyes) with acute-stage VKH disease were studied. All underwent fundus fluorescein angiography (FFA), ultrasonography, and spectral-domain optical coherence tomography (SD OCT). The main outcome measure was the correlation of the findings seen on a 3-dimensional (3D) single-layer RPE map constructed on SD OCT ... (Read Full Article)
Comment on Article Mentions: Amod Gupta Carl Zeiss Meditec Zeiss Cirrus HD-OCT
-
Evaluation of Time Domain and Spectral Domain Optical Coherence Tomography in the Measurement of Diabetic Macular Edema
iovs.org (Oct 1 2008) Ophthalmology Explore Article
...y in two optical coherence tomography (OCT) systems: the Stratus OCT, a time domain system, and the Cirrus HD-OCT, a spectral domain system (both by Carl Zeiss Meditec, Inc., Dublin, CA), in the context of diabeti... (Read Full Article)
Comment on Article Mentions: Carl Zeiss Meditec Zeiss Cirrus HD-OCT Zeiss Stratus OCT
-
Retinal atrophy using optical coherence tomography (oct) in 15 patients with multiple sclerosis and comparison with healthy subjects.
NCBI HomePage (Sep 24 2008) Ophthalmology Explore Article
Authors: Jeanjean L, Castelnovo G, Carlander B, Villain M, Mura F, Dupeyron G, Labauge P INTRODUCTION: Multiple sclerosis is a common disabling progressive neurological disorder. Axonal loss is thought to be a likely cause of persistent disability after a multiple sclerosis relapse. Retinal nerve fiber layer (RNFL) imaging by optical coherence tomography (OCT) seems to be a non-invasive way of detecting optical axonal loss following optic neuritis. OBJECTIVE: To determine ... (Read Full Article)
Comment on Article Mentions: Carl Zeiss Meditec Zeiss Cirrus HD-OCT
-
New technology to help detect retinal disease acquired by WHC
Home - Daily Democrat Online (Sep 19 2008) Ophthalmology Explore Article
...logists advanced imaging capabilities to assess and manage glaucoma and diseases of the retina. The Cirrus HD-OCT provides detailed scan patterns and layer maps for identifying retinal and glaucoma disease charact... (Read Full Article)
Comment on Article Mentions: Zeiss Cirrus HD-OCT Carl Zeiss Meditec
-
Carl Zeiss Meditec: Largest base of optical coherence technology worldwide with more than 10.000 units installed
AKTIENKURSE & AKTIEN NEWS (Sep 11 2008) Ophthalmology Explore Article
Carl Zeiss Meditec Largest base of Ad-Hoc-News (Pressemitteilung), Germany - 6 hours agoOptical coherence tomography (OCT) is an imaging method that uses light to scan the retina, and can be performed on undilated pupils as small as 3 mm in ... (Read Full Article)
Comment on Article Mentions: Carl Zeiss Meditec Carmen A. Puliafito Zeiss Cirrus HD-OCT
-
Spectral Domain Optical Coherence Tomography Imaging of Retinal Diseases in Singapore
osli.com (Sep 10 2008) Ophthalmology Explore Article
...r disorders whose eyes had been imaged using spectral domain optical coherence tomography (SD-OCT) (Cirrus HD-OCT; Carl Zeiss Meditec, Inc., Dublin, CA). SD-OCT images were obtained from patients with a variety of... (Read Full Article)
Comment on Article Mentions: Carl Zeiss Meditec Zeiss Cirrus HD-OCT
-
Retinal Angiomatous Proliferation: Morphological Changes Assessed by Stratus and Cirrus OCT
osli.com (Sep 10 2008) Ophthalmology Explore Article
...ents with RAP underwent retinal thickness imaging with Stratus OCT and cube 200 × 200 imaging with Cirrus OCT. RESULTS A total of 12 eyes from 11 patients were included in the study. Of these, eight ey... (Read Full Article)
Comment on Article Mentions: Carl Zeiss Meditec Zeiss Cirrus HD-OCT
-
Spectral Domain High-definition Optical Coherence Tomography in Patients Undergoing Epiretinal Membrane Surgery
osli.com (Sep 10 2008) Ophthalmology Explore Article
...th visual acuity (VA) and metamorphopsia. RESULTS Five consecutive patients were enrolled. With Cirrus HD-OCT, it was possible to differentiate between the ERM and the retinal surface in all patients. In areas... (Read Full Article)
Comment on Article Mentions: Carl Zeiss Meditec Zeiss Cirrus HD-OCT
-
Comparison of Macular Thickness Between Cirrus HD-OCT and Stratus OCT
osli.com (Sep 10 2008) Ophthalmology Explore Article
...hicknesses in healthy subjects measured with spectral domain optical coherence tomography (SD-OCT) (Cirrus; Carl Zeiss Meditec, Inc., Dublin, CA) with measurements using time domain (TDOCT) (Stratus; Carl Z... (Read Full Article)
Comment on Article Mentions: Carl Zeiss Meditec Zeiss Cirrus HD-OCT Zeiss Stratus OCT






Recent Comments
Eric Swanson » The Evolution of Spectral Domain OCT
For more information see http://octnews.hivefire.com/entity/profile/oct-information-on-ophthalmology-website/
bernie » Morphology and Epidermal Thickness of Normal Skin Imaged by Optical Coherence Tomography.
Interesting
See all recent comments